Procedural characteristics of pulmonary vein isolation with high

Procedural characteristics of pulmonary vein isolation with high

4.7
(505)
Write Review
More
$ 12.00
Add to Cart
In stock
Description

The purpose of this study was to investigate the safety and efficacy of high-power short-duration (HP-SD) ablation compared to conventional ablation in patients with atrial fibrillation (AF). We enrolled consecutive 158 drug-refractory symptomatic AF patients (119 males, mean age 63 ± 10 years) who had undergone first radiofrequency pulmonary vein isolation (PVI). PVI was performed using the conventional setting (20–35 W) in 73 patients (Conventional group) and using the HP-SD setting (45–50 W) in 85 patients (HP-SD group). The rate of first pass isolation, remaining gaps after circumferential ablation, dormant conduction, and the radiofrequency application time in each pulmonary vein (PV) were compared between the groups. The first pass isolation ratio was significantly higher in the HP-SD group than in the Conventional group (81% vs. 65%, P = 0.027) in the right PV, but did not differ in the left PV. The remaining gaps were fewer in the right superior PV (4% vs. 21%, P = 0.001) and left inferior PV (1% vs. 8%, P = 0.032) areas, and the radiofrequency application time in each PV was shorter (right PV, 12.0 ± 8.9 min vs. 34.0 ± 31.7 min, P < 0.001; left PV, 10.6 ± 3.6 min vs. 25.7 ± 22.3 min, P < 0.001) in the HP-SD group than in the Conventional group. The use of the HP-SD setting might contribute to improve the first pass isolation rate and to shorten the radiofrequency application time in each PV.

Procedural characteristics of pulmonary vein isolation with high

High incidence of atrial fibrillation after successful catheter

Atrio-Esophageal Fistula as a Complication of Percutaneous Transcatheter Ablation of Atrial Fibrillation

Frontiers Impact of High-Power and Very High-Power Short-Duration Radiofrequency Ablation on Procedure Characteristics and First-Pass Isolation During Pulmonary Vein Isolation

Pulsed Field Ablation for Pulmonary Vein Isolation in Atrial

Electroporation and its Relevance for Cardiac Catheter Ablation

Comparison of the PolarX and the Arctic Front cryoballoon for

Procedural success, safety and patients satisfaction after second

Feasibility and safety of pulmonary vein isolation by high-power short-duration radiofrequency application: short-term results of the POWER-FAST PILOT study

PDF) Complete biatrial ablation of atrial fibrillation with bipolar radiofrequency

Prospective use of Ablation Index targets improves clinical outcomes following ablation for atrial fibrillation

Focus on EP Single-shot Techniques For Pulmonary Vein Isolation in AFib: From Cryoablation to Pulse Field Ablation - American College of Cardiology

Evaluation of cryoballoon pulmonary vein isolation lesions during